| Model | Capacity | Size For | Air Flow | COP |
|---|---|---|---|---|
|
120 PPD (Sat) / 55 (AHAM) | 1300 sq. ft. | 130 CFM, 230CMH | 2.4 L/Kwh |
|
70 PPD (Sat) / 35 (AHAM) | Up to 1,000 sq. ft. | 115CFM,195CMH | 2.0 L/kWh |
|
70 PPD (Sat) / 35 (AHAM) | 1,000 Sq.Ft | 126 CFM-215CMH | 2.12L/kWh |
|
120 PPD (Sat) / 55 (AHAM) | 1,500 Sq.Ft | 167 CFM-285CMH | 2.08L/kWh |
|
70 PPD (Sat) / 35 (AHAM) | Up to 1,000 sq.ft. | 115CFM,195CMH | 2.0 L/kWh |
|
70 PPD (Sat) / 35 (AHAM) | 1,000 sq.ft. | 97 CFM, 165 CMH | 2.85 L/kWh |
|
120 PPD (Sat) / 55 (AHAM) | 1,300 sq. ft | 130 CFM, 230CMH | 2.4 L/Kwh |
|
145 PPD (Sat) / 60 (AHAM) | 1,800 Sq.Ft | 165CFM 280CMH | 2.4L/KWh |
|
145 PPD (Sat) / 60 (AHAM) | 1,800 Sq.Ft | 165CFM 280CMH | 2.4L/KWh |
|
180 PPD (Sat) / 85 (AHAM) | 2,300 sq. ft | 194CFM 330CMH | 2.7 L/kWh |
|
113 PPD (Sat) / 53 (AHAM) | 1,200 sq. ft | 120 CFM, 205 CMH | 2.27 L/kWh |
|
120 PPD (Sat) / 55 (AHAM) | 1300 sq. ft. | 130 CFM, 230CMH | 2.4 L/Kwh |
|
70 PPD (Sat) / 35 (AHAM) | 1000 Sq Ft | 115CFM,195CMH | 2.0 L/kWh |
|
113 PPD (Sat) / 53 (AHAM) | 1200 sq. ft. | 120 CFM, 205 CMH | 2.27 L/kWh |
|
120 PPD (Sat) / 55 (AHAM) | Up to 1,300 Sq.Ft. | 130 CFM, 230 CMH | 2.4 L/Kwh |
|
120 PPD (Sat) / 55 (AHAM) | Up to 1,300 sq. ft. | 130 CFM, 230CMH | 2.4 L/Kwh |
|
70 PPD | 1,000 Sq.Ft | 540 CFM | 2.0 L/kWh |
|
145 PPD | 1,800 sq. ft | 540 CFM | 2.4 L/KWh |
|
198 PPD (Sat) / 90 (AHAM) | 2600 sq.ft | 210 CFM, 350 CMH | 2.69L/KWh |
|
235 PPD (Sat) / 120 (AHAM) | 3,300 Sq.Ft | 290 CMH | 2.7 L/Kwh |
|
235 PPD | 3,300 Sq.Ft | 720 CFM | 2.7 L/Kwh |
|
198 PPD (Sat) / 90 (AHAM) | Up to 2,600 sq. ft. | 210 CFM, 350 CMH | 2.69L/KWh |
|
198 PPD (Sat) / 90 (AHAM) | 2600 sq.ft | 210 CFM, 350 CMH | 2.69L/KWh |
|
198 PPD (Sat) / 90 (AHAM) | 2600 sq.ft | 210 CFM, 350 CMH | 2.69L/KWh |
|
120 PPD (Sat) / 55 (AHAM) | 1,300 sq. ft | 153CFM,260CMH | 2.3 L/kWh |
|
120 PPD | 1,500 Sq.Ft | 260 CFM | 2.3 L/kWh |
|
198 PPD | 2600 sq. ft | 210 CFM | 2.69 L/KWh |
|
2×70 PPD | 2×1,000 Sq.Ft | 540 CFM | 2.85 L/kWh |
|
220 PPD (Sat) / 100 (AHAM) | 2900 sq. ft. | 250CMH | 2.7 L/Kwh |
|
220 PPD | 2,900 Sq.Ft | 780 CFM | 2.7 L/Kwh |
| Problem | Cause | Solution |
|---|---|---|
| Machine Won't Run | Power supply issue | Confirm power to the outlet and proper plug installation. |
| Room temperature is over 104°F (Display HI) or below 33.8°F (Display LO) | The dehumidifier is experiencing operation issues due to being subjected to temperatures outside the optimal range. Adjust ambient conditions to maintain a temperature within the range of 33.8°F to 104°F, and the unit will initiate its operation. | |
| Low Air Flow | Air filter is clogged | Replace the filter. |
| Air inlet or outlet is blocked | Clear the blockage from the inlet or outlet. | |
| Loud Noise | Machine is not level | Move the dehumidifier to flat, firm ground. |
| Filter mesh is blocked | Replace the filter. | |
| Trouble Code: E1 | Humidity Sensor Issues | Ensure the wire is connected at both ends. If no issues are visible, the sensor may be faulty. Replace defective sensor. |
| Trouble Code: HI or LO | Room temperature is over 104°F (Display HI) or below 33.8°F (Display LO) | The dehumidifier is experiencing operation issues due to being subjected to temperatures outside the optimal range. Adjust ambient conditions to maintain a temperature within the range of 33.8°F to 104°F, and the unit will initiate its operation. If room temperatures are within the temperature range, the sensor may be faulty. Replace defective sensor. |
| Trouble Code: E3 | Abnormal coil temperature | Contact your installer for assistance. |
| Trouble Code: E4 | Water full alarm | Check whether water pipes are clogged or bent. |
| Trouble Code: E5 | Refrigerant leak | Contact your installer for assistance. |